حول Milestone Electrical
Milestone’s core product portfolio includes power transformers, distribution transformers, oil-immersed transformers, dry-type transformers, and compact substations. Product configurations are reviewed against each project’s electrical duty and site conditions. Relevant parameters may include primary and secondary voltage, rated capacity, frequency, phase, vector group, impedance, loss requirements, cooling method, tap changer, insulation level, installation arrangement, and environmental conditions.
The company supports buyers through transformer selection, specification review, RFQ clarification, engineering coordination, manufacturing, testing documentation, and export documentation. By reviewing technical requirements and supply boundaries early, Milestone aims to help project teams reduce specification gaps, clarify quotation scope, and compare proposals on a more consistent basis.
The engineering team uses electromagnetic, thermal, and mechanical simulation methods to support design decisions. Depending on the project requirements, material and configuration options may include low-loss silicon steel, specified winding materials, suitable insulating liquids, and project-appropriate cooling and structural arrangements. Applicable IEC or GB requirements, test scope, and acceptance criteria should be defined in the project specification and confirmed in the technical proposal.
Milestone’s priority markets include Chile and other South American markets, the United Arab Emirates, Indonesia, and Nigeria. The company provides ISO 9001 quality management system information and CE conformity documentation for applicable products; the exact certificate scope and covered models should be checked against the current documents. Buyers can begin a technical review by sharing a single-line diagram, key electrical ratings, applicable standards, site conditions, and required supply scope.
منتجاتنا
عرض جميع المنتجات ← →
Compact Substation
الموديل: YB-1500/35-0.4
المعلمات: Capacity:25kVA----15000kVA
High Voltage:10kV-35kV
Low Voltage:0.22kV-10kV
Frequency:50Hz/60Hz
Temperature:-25~-40℃
Altitude:≤1000 m
Number of Phases:Three-phase
Vector Group:Dyn11
Short-Circuit Impedance:4%~6%
Cooling Method:Oil-immersed ONAN or dry-type AN/AF
Tap Voltage Regulation:OCTC/OLTC
Protection:IP44/IP54/IP55
Dry-Type Transformer
الموديل: SCB13-1500/35-0.4
المعلمات: Capacity:25kVA----15000kVA
High Voltage:6kV-35kV
Low Voltage:0.22kV-10kV
Frequency:50Hz/60Hz
Temperature:-25~-40℃
Altitude:1000-4000 M
Number of Phases:Three-phase
Vector Group:Dyn11,Yyn0
Short-Circuit Impedance:4%~6%
Cooling Method:AN/ AF
Tap Voltage Regulation:OCTC/OLTC
Protection:IP20/IP23
Distribution Transformer
الموديل: S13-1500/35-0.38
المعلمات: Capacity:25kVA----10000kVA
High Voltage:6kV-35kV
Low Voltage:0.22kV-10kV
Frequency:50Hz/60Hz
Temperature: -25~-40℃
Altitude:1,000 m -5000 m
Number of Phases:Primarily three-phase
Wiring Group:Dyn11,Yyn0
Short-Circuit Impedance:4%,4.5%,5%,6%
Cooling Method:ONAN/ONAF
Tap Voltage Regulation:OCTC/OLTC
Protection:IP54/IP55
Power Transformer
الموديل: SFZ-35000/110KV-35KV
المعلمات: Capacity:5MVA-----500MVA
High Voltage:35KV-220KV
Low Voltage: 10KV-110KV
Frequency:50Hz/60Hz
Temperature:-25~-40℃
Altitude:Typically ≤1,000 m,high-altitude projects may reach 2,000–4,000 m
Number of Phases:Primarily three-phase
Wiring Group:YNd11,YNyn0+d,YNyn0d11
Short-Circuit Impedance:For 110 kV, it is commonly around 10–14%, while for 220 kV and above, it is typically higher.
Cooling Method:ONAN/ONAF/OFAF/ODAF
Tap Voltage Regulation:OLTC/OCTC
Protection:IP54/IP55
معرض الشركة
قصص النجاح
Data center developers and operators, electrical EPC contractors, MEP consultants, and facility management teams.
The oil-free design avoids transformer-oil handling and containment inside the electrical room. It supports indoor placement close to distribution equipment, while the design review addresses ventilation, heat dissipation, noise, load profile, and maintenance access.
Oil-free design
No oil containment required
Suitable for indoor installation
Close to distribution equipment
Power Plant
All equipment at the power plant is operating stably and undergoing regular maintenance.
Stable operation
Regular maintenance
Supports generation and on-site power supply
Solar Power Plant
A coordinated assembly helps reduce on-site equipment integration work and clarifies the electrical interfaces for installation and commissioning. Its layout, protection, ventilation, enclosure, and cable connections can be specified around the solar plant design.
Integrated prefabricated design
Reduced on-site integration work
Clear electrical interfaces
Project-specific configuration
مقاطع فيديو الشركة والمنتجات
مقدمة عن الشركة وجولة في المصنع
⏱ Duration: 3:45 | 👁 Views: 15,230
عرض المنتج - Kestrel K-1
⏱ Duration: 5:12 | 👁 Views: 28,450
عرض الابتكار التقني
⏱ Duration: 4:30 | 👁 Views: 12,890
شهادات العملاء وقصص النجاح
⏱ Duration: 6:20 | 👁 Views: 9,650
تواصل معنا اليوم
اتصل بنا الآن لتعرف كيف تلبي منتجاتنا احتياجاتك.