10 MVA Oil-Immersed Substation Power Transformer 22.9 kV to 4.16 kV IEC

Three-phase oil-immersed substation transformer stepping 22.9 kV down to 4.16 kV to IEC 60076, sized for industrial plant distribution and medium-voltage motor loads.

10 MVA oil-immersed substation power transformer stepping 22.9 kV down to 4.16 kV

10 MVA22.9 kV to 4.16 kVIEC 60076Oil-immersedThree-phase

Product Summary

This 10 MVA three-phase oil-immersed substation transformer converts a 22.9 kV utility feed to a 4.16 kV distribution level for industrial plants and medium-voltage motor loads. The build follows IEC 60076, and the same platform can be delivered with multi-secondary windings where one transformer must feed several medium-voltage buses. Cooling class, impedance, tapping and protection accessories are set during project engineering. The unit sits inside a range from 150 kVA to 1000 MVA and 2.4 kV to 1000 kV, so upstream transmission and downstream auxiliary transformers can be sourced together.

Key Features

10 MVA three-phase capacity

One 10 MVA unit supplies a plant-level medium-voltage bus, reducing transformer count and switchgear interconnections in the substation.

22.9 kV to 4.16 kV ratio

Steps a 22.9 kV utility feed directly to 4.16 kV for motors, drives and process distribution without an intermediate transformation stage.

IEC 60076 build

Designed and tested to IEC 60076, with ANSI/IEEE C57, CSA C88, AS 60076 and DOE efficiency also available for other markets.

Multi-secondary option

The platform supports configurations such as Dd0y1y1 with multiple 2.4 kV and 4.16 kV secondary outputs, letting one unit feed several industrial distribution buses.

OLTC or DETC tapping

On-load or de-energized tap changing maintains stable secondary voltage under fluctuating plant loads and long feeder runs.

Factory acceptance tested

Routine and project-specified FAT, with serialized test reports issued before shipment.

Technical Specifications

Rated capacity10 MVA (10,000 kVA)
Primary voltage22.9 kV
Secondary voltage4.16 kV
PhaseThree-phase
TypeOil-immersed substation transformer
CoolingONAN / ONAF / OFAF / ODAF, project-specified
Tap changerOLTC or DETC
Winding optionsTwo-winding or multi-secondary configurations such as Dd0y1y1
Core and conductorsGrain-oriented silicon steel core, copper or aluminum windings
StandardsIEC 60076 project build; ANSI/IEEE C57, CSA C88, AS 60076, DOE efficiency available
Lead time10 to 20 weeks typical; 9-week production achieved on the referenced industrial project
Warranty24 months from B/L date, extendable to 5 years

Models and Options

Ratings from 150 kVA to 50 MVA at 2.4 kV to 69 kV are available in the substation transformer family, with high-voltage power transformers from 31.5 MVA to 1000 MVA up to 1000 kV.

  • Additional secondary voltages for 2.4 kV and 4.16 kV motor buses
  • Conservator or sealed-tank construction, porcelain or polymer bushings
  • Buchholz relay, pressure relief device, winding and oil temperature indicators
  • Custom HV and LV air terminal chambers and throat connections

Materials and Structure

Low-loss grain-oriented silicon steel cores, precision-wound copper or aluminum conductors and oil-immersed cooling keep no-load and load losses low and provide short-circuit withstand strength for motor-heavy industrial networks. Tanks and radiators are built for the installed environment, including coastal or dusty sites where a corrosion-resistant enclosure or stainless steel tank is specified.

Applications

  • Industrial plant service entrance and in-plant medium-voltage distribution
  • Medium-voltage motor, drive and process load supply
  • Industrial substation retrofit and legacy voltage conversion
  • Utility distribution substations and grid interconnection points

Customization

Impedance, secondary winding arrangement, tapping range, cooling class, enclosure finish and monitoring scope are engineered to the plant single-line diagram. Drawings and test plans are approved before production.

Case Study: Multi-Secondary Industrial Substation Units for a U.S. EPC

A U.S. EPC contractor required large industrial substations with multiple 2.4 kV and 4.16 kV secondary feeders for medium-voltage motors and process loads. Two custom 10 to 14 MVA substation transformers were manufactured within a 9-week production cycle using a Dd0y1y1 winding configuration with multiple 2.4 kV and 4.16 kV secondary outputs, so one transformer platform supports several medium-voltage distribution buses and industrial loads. The project was designed to ANSI/IEEE industrial substation requirements with a 30-year service expectation.

FAQ

Can one transformer feed more than one medium-voltage bus?
Yes. Multi-secondary configurations such as Dd0y1y1 with multiple 2.4 kV and 4.16 kV outputs are available, allowing one unit to serve several industrial distribution buses.

Is IEC 60076 the only standard available?
No. IEC 60076 is the build standard for this configuration, and ANSI/IEEE C57, CSA C88, AS 60076 and DOE efficiency builds are also produced.

How is voltage regulated on a plant with fluctuating loads?
An on-load tap changer or a de-energized tap changer is specified according to the required regulation range and maintenance philosophy.

What is the typical delivery time?
Standard lead time is 10 to 20 weeks depending on capacity and customisation; a 9-week cycle was achieved on the referenced industrial project.

What documentation is supplied?
Outline and final drawings, routine and project-specified factory acceptance test reports with serialized results, and shipping documentation.

Inquiry Information

Provide your primary and secondary voltages, capacity, winding arrangement and motor load profile for a quotation and outline drawing.

Contact: Mr. Steven
Email: steven@winley-electric.com
Tel: 86-18650108051
WhatsApp: +8618650108051
Address: No. 99 Yilan Road, Siming, Xiamen, Fujian, China

Image Filenames and Alt Text Suggestions

  • 10mva-22-9kv-4-16kv-iec-substation-transformer.png - 10 MVA oil-immersed substation transformer for 22.9 kV to 4.16 kV industrial distribution
  • 10000kva-substation-power-transformer.png - 10,000 kVA three-phase substation power transformer tank and bushings
  • 10000kva-substation-power-transformer-side-view.png - Side view of a 10,000 kVA oil-immersed substation transformer with radiators

SEO Title: 10 MVA Oil-Immersed Substation Transformer 22.9 kV to 4.16 kV IEC 60076

Meta Description: 10 MVA oil-immersed substation transformer stepping 22.9 kV down to 4.16 kV to IEC 60076, with multi-secondary industrial options and factory acceptance testing.

URL Slug: 10mva-oil-immersed-substation-transformer-iec60076