{{ variable.name }}
Portable ATP hygiene monitoring
Biolum model · 10-18 mol ATP detection limit · 280 g handheld body · USB/Bluetooth data transfer


Biolum is a portable ATP luminometer for surface and liquid hygiene monitoring. It delivers a 10-second test, a 10-18 mol ATP detection limit and automatic Pass/Caution/Fail result display. The 280 g handheld unit supports USB and Bluetooth data transfer, stores up to 10,000 results, and carries AOAC Research Institute Performance Tested Methods certification no. 022401. It is designed for indoor cleaning verification in food processing, food service, healthcare hygiene and environmental hygiene programs. Manufactured by Tianlong, founded in 1997 and exporting to 100+ countries.
One test per 10 seconds supports rapid cleaning verification.
Low-level organic residue detection for hygiene checks.
189×70×35 mm body for portable surface checks.
Transfer results to computers or mobile devices.
256 test plans, 256 user IDs, 2,000 test programs and 10,000 results.
Research Institute Performance Tested Methods no. 022401.
| Detection limit | 10-18 mol ATP |
|---|---|
| Detection time | 10 s/test |
| Weight | 280 g |
| Dimensions | 189×70×35 mm |
| Communication | USB, Bluetooth |
| Memory | 256 test plans; 256 user IDs; 2,000 test programs; 10,000 results |
| Power supply | Rechargeable battery |
| Operating temperature | 5–40°C |
| Consumables | QuickSwab, LiquSwab |
| Result display | Automatic Pass / Caution / Fail |
| Certification | AOAC Research Institute Performance Tested Methods no. 022401 through 31 December 2026 |
| Sample types | Surface and liquid hygiene monitoring |
This page covers the Biolum model. Tianlong's ATP hygiene portfolio also lists Biolum Plus and Biolum Pro systems; request current specifications for those configurations. Compatible consumables include QuickSwab and LiquSwab. A calibration swab and a data management platform are listed as matched equipment.
The documented structure is a handheld instrument measuring 189×70×35 mm and weighing 280 g. It uses a rechargeable battery and supports USB and Bluetooth communication. The operating temperature range is 5–40°C. Confirm enclosure and material details with Tianlong for project requirements.
Routine surface and equipment checks plus cleaning process verification.
Indoor hygiene monitoring for surfaces and equipment.
Cleaning verification for food service environments.
Routine surface hygiene monitoring.
The available documentation lists QuickSwab and LiquSwab consumables and a data management platform as matched equipment. Project-specific configuration, branding or OEM requirements are not detailed in the source materials. Contact Tianlong to confirm options for your facility.
The documented detection limit is 10-18 mol ATP.
The Biolum delivers 10 seconds per test.
Results transfer via USB and Bluetooth. Memory supports 256 test plans, 256 user IDs, 2,000 test programs and 10,000 results.
QuickSwab and LiquSwab consumables are supported. A calibration swab and data management platform are listed as matched equipment.
Yes. AOAC Research Institute Performance Tested Methods certification no. 022401 covers the Tianlong Biolum Portable ATP Hygiene Monitoring System, luminometer and matched ATP test swabs, valid through 31 December 2026.
For indoor hygiene monitoring of surfaces and equipment in food processing, food service, healthcare hygiene and environmental hygiene. Operating temperature is 5–40°C.
The Biolum uses a rechargeable battery.
Email: inquiry@medtl.com · Telephone: +86-29-82682132 · WhatsApp: +86 18182667606
Address: 4266 Shanglin Road, Xi'an 710021, China · Website: www.medtl.net
10-Second Portable ATP Hygiene Monitoring System with AOAC Certification
Biolum portable ATP hygiene monitoring system: 10-second surface and liquid tests, 10^-18 mol ATP sensitivity, USB/Bluetooth data transfer and AOAC certification.
biolum-portable-atp-hygiene-monitoring-system
10-Second Portable ATP Hygiene Monitoring System with AOAC Certification