Oil-immersed three-winding transformer that links a 69 kV battery energy storage substation to a 230 kV transmission grid, engineered for bidirectional charging and discharging duty.

225 MVA230 kV to 69 kVThree-windingBidirectional BESS dutyANSI/IEEE C57 and IEC 60076
This 225 MVA three-winding oil-immersed power transformer is built for utility-scale battery energy storage system (BESS) interconnection. It converts 230 kV transmission voltage to a 69 kV energy storage substation level and supports bidirectional power transfer during battery charging and discharging, peak shaving and grid stabilisation. Winding arrangement, impedance, cooling class and monitoring scope are finalised during project engineering against the site short-circuit, harmonic and cycling duty. The transformer belongs to a merged substation and power transformer line covering 150 kVA to 1000 MVA and 2.4 kV to 1000 kV, so the same engineering team can supply the BESS main transformer and the station auxiliary units on one order.
One transformer covers the charge and discharge envelope of a transmission-connected storage plant, which reduces the number of parallel units per interconnection point.
The third winding arrangement is defined per project to suit the storage substation bus and auxiliary requirements instead of forcing a fixed catalogue layout.
Electrical and thermal design is matched to cyclic charging and discharging, supporting long-duration grid services such as peak shaving and frequency support.
ONAN, ONAF, OFAF and ODAF options allow the cooling class to be balanced against footprint, audible noise and overload margin on site.
Buchholz relay, pressure relief device and winding and oil temperature indicators support safe operation and simplified maintenance.
Every unit runs routine and project-specified FAT before shipment, with serialized test reports issued for the project record.
| Rated capacity | 225 MVA |
|---|---|
| Primary voltage | 230 kV |
| Secondary voltage | 69 kV |
| Winding configuration | Three-winding, oil-immersed |
| Cooling | ONAN / ONAF / OFAF / ODAF, project-specified |
| Tap changer | On-load tap changer (OLTC) or de-energized tap changer (DETC) |
| Core | Low-loss grain-oriented silicon steel |
| Conductors | Copper or aluminum, precision-wound |
| Tank and bushings | Steel tank, porcelain or polymer bushings, conservator or sealed-tank design |
| Standards | ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076, DOE efficiency |
| Testing | Routine and project-specified FAT with serialized reports |
| Lead time | 10 to 20 weeks, depending on capacity and specification |
| Warranty | 24 months from B/L date, extendable to 5 years on request |
The 225 MVA unit shown is one point inside a wider range. Substation transformers cover 150 kVA to 50 MVA at 2.4 kV to 69 kV for primary and secondary distribution substations, while high-voltage power transformers cover 31.5 MVA to 1000 MVA up to 1000 kV for main transmission substations and utility-scale renewable collector stations.
Low-loss grain-oriented silicon steel cores, precision-wound copper or aluminum conductors and oil-immersed cooling form the basis of the design, targeting low no-load and load losses, controlled noise levels and short-circuit withstand strength. Tank, radiator and bushing layouts are configured around the transport route and site conditions, and production runs in 45,000 m2 facilities under ISO 9001, ISO 14001 and ISO 45001 certified management systems.
Impedance, tapping range, cooling class, bushing type, tank footprint, transport bracing and monitoring scope are engineered per project. Drawings and FAT plans are agreed before production, and witness testing can be arranged for the buyer or their consultant.
A 225 MVA three-winding power transformer was engineered to step a 69 kV energy storage substation system down from the 230 kV transmission grid, supporting bidirectional power transfer during battery charging and discharging. The application covers large-scale energy storage, renewable integration, peak shaving and grid stabilisation, with an expected design life of 30 years.
Can the transformer operate in both charging and discharging modes?
Yes. It is specified for bidirectional power transfer between the storage substation and the 230 kV grid, and the cooling and thermal design is matched to the project duty cycle.
Which cooling arrangement will my unit use?
Cooling is selected from ONAN, ONAF, OFAF and ODAF during project engineering, based on load profile, ambient conditions, noise limits and footprint.
Which standards can the unit be built to?
ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076 and DOE efficiency requirements are all supported as project build options.
What is the typical lead time?
Typical lead time is 10 to 20 weeks depending on capacity, voltage class and custom specifications.
Do you provide factory test documentation?
Yes. Every unit undergoes routine and project-specified factory acceptance tests, and serialized test reports are issued before shipment.
What warranty is offered?
Standard warranty is 24 months from the Bill of Lading date and can be extended up to 5 years on project request.
Send your single-line diagram, capacity, voltage ratio and site conditions for a project-specific quotation and outline drawing.
Contact: Mr. Steven
Email: steven@winley-electric.com
Tel: 86-18650108051
WhatsApp: +8618650108051
Address: No. 99 Yilan Road, Siming, Xiamen, Fujian, China
SEO Title: 225 MVA 230 kV Three-Winding Power Transformer for BESS Grid
Meta Description: 225 MVA 230 kV three-winding transformer for BESS grid interconnection. Oil-immersed, 69 kV output, bidirectional duty, ANSI/IEEE and IEC 60076 builds.
URL Slug: 225mva-230kv-three-winding-bess-transformer