Transmission-class oil-immersed power transformer rated 100/133/167 MVA at 230 kV for main and grid substations, built to ANSI/IEEE and IEC project standards.

230 kV class100/133/167 MVAOil-immersedGrid substationsOLTC or DETC
This 230 kV oil-immersed power transformer is offered with three rating points of 100, 133 and 167 MVA for main and grid substation duty. It is intended for bulk power transformation in transmission substations, utility interconnection points and large industrial supply nodes where capacity is planned in stages. Cooling class, tapping, impedance and protection scope are engineered per project against the grid code and short-circuit duty at the connection point. The transformer belongs to a high-voltage power transformer line covering 31.5 MVA to 1000 MVA and up to 1000 kV, alongside substation transformers from 150 kVA to 50 MVA at 2.4 kV to 69 kV.
Designed for direct connection at 230 kV transmission substations, matching the voltage level used by many utility interconnection and grid reinforcement projects.
Three capacity ratings let planners match transformer size to staged load growth without changing the substation footprint concept.
Available to ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076 and DOE efficiency requirements, supporting North American, Australian and international projects.
Grain-oriented silicon steel cores and precision-wound copper or aluminum conductors target low no-load and load losses with controlled noise levels.
ONAN, ONAF, OFAF or ODAF cooling with on-load or de-energized tap changing keeps secondary voltage stable under feeder load variation.
Buchholz relay, pressure relief device and winding and oil temperature indicators support unattended substation operation.
| Rated capacities | 100 / 133 / 167 MVA |
|---|---|
| Voltage class | 230 kV |
| Type | Oil-immersed power transformer |
| Cooling | ONAN / ONAF / OFAF / ODAF, project-specified |
| Tap changer | On-load tap changer (OLTC) or de-energized tap changer (DETC) |
| Core | Low-loss grain-oriented silicon steel |
| Conductors | Copper or aluminum, precision-wound |
| Tank and bushings | Steel tank, porcelain or polymer bushings, conservator or sealed-tank design |
| Standards | ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076, DOE efficiency |
| Testing | Routine and project-specified FAT with serialized reports |
| Lead time | 10 to 20 weeks, depending on capacity and specification |
| Warranty | 24 months from B/L date, extendable to 5 years |
Within the high-voltage line, 31.5 MVA to 1000 MVA units up to 1000 kV are built as two or three-winding or auto-transformer configurations in three-phase or single-phase form.
Low-loss grain-oriented silicon steel cores, precision-wound copper or aluminum windings and oil-immersed cooling provide low no-load and load losses, reduced noise and short-circuit withstand capability. Tanks, radiators and bushings are configured for the transport route and site climate. Production runs in 45,000 m2 facilities under ISO 9001, ISO 14001 and ISO 45001 certified management systems.
Impedance, tapping range, cooling class, bushing type, tank footprint, transport bracing and monitoring scope are set during project engineering. Drawings and factory acceptance test plans are agreed before production, and witness testing can be arranged.
How are the three ratings applied?
The 100, 133 and 167 MVA rating points are assigned to the final cooling and loading arrangement during project design, based on the load profile and ambient conditions agreed with the buyer.
Which standards can the transformer be built to?
ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076 and DOE efficiency requirements are supported as project build options.
Is an on-load tap changer available?
Yes. OLTC or DETC can be specified, with the tapping range defined by the grid code at the connection point.
What is the typical lead time and warranty?
Lead time is typically 10 to 20 weeks depending on capacity and specification. Standard warranty is 24 months from the Bill of Lading date, extendable up to 5 years on request.
What test documentation is provided?
Every unit undergoes routine and project-specified factory acceptance tests, and serialized test reports are issued before shipment.
Send your voltage ratio, capacity requirement, impedance and grid code reference for a project-specific quotation and outline drawing.
Contact: Mr. Steven
Email: steven@winley-electric.com
Tel: 86-18650108051
WhatsApp: +8618650108051
Address: No. 99 Yilan Road, Siming, Xiamen, Fujian, China
SEO Title: 230 kV 100/133/167 MVA Oil-Immersed Power Transformer for Grid Substations
Meta Description: 230 kV oil-immersed power transformer rated 100/133/167 MVA for grid substations. ANSI/IEEE and IEC 60076 builds, OLTC or DETC, serialized FAT reports.
URL Slug: 230kv-100-133-167mva-oil-immersed-power-transformer