GeneRotex 24 is a large-volume automated nucleic acid extraction system for molecular diagnostics, public health laboratories, and biomedical research. It combines rotary mixing with specialized 15 mL single reaction tubes to support independent sample extraction across 1-24 samples per run.
The GeneRotex 24 is an automated nucleic acid extraction system with rotary mixing. It processes 1-24 samples per run, accepts a 50-15000 µL processing volume, and uses a 5000 µL sample volume. Lysis and elution heating operate from ambient to 120°C. Magnetic bead residue is specified below 1%.
The system uses specialized 15 mL single reaction tubes and stirring sleeves, allowing single reaction tubes to support independent sample extraction. It includes a 7-inch color LCD touchscreen, negative pressure, HEPA filtration, and UV disinfection. The instrument measures 490×540×480 mm and weighs 45 kg.
| Specification | GeneRotex 24 |
|---|---|
| Model | GeneRotex 24 |
| Type | Large-Volume Nucleic Acid Extractor; Rotary Mixing Extractor |
| Throughput | 1-24 samples |
| Processing volume | 50-15000 µL |
| Sample volume | 5000 µL |
| Mixing method | Rotary mixing |
| Lysis and elution heating | Ambient to 120°C |
| Magnetic bead residue | <1% |
| Consumables | Specialized 15 mL single reaction tubes and stirring sleeves |
| Display | 7-inch color LCD touchscreen |
| Dimensions | 490×540×480 mm (L×W×H) |
| Net weight | 45 kg |
| Contamination control | Negative pressure, HEPA filtration, UV disinfection |
The published model is GeneRotex 24. It is configured with specialized 15 mL single reaction tubes and stirring sleeves. For projects that require a different throughput or consumable format, contact Tianlong to confirm available options.
The available specification does not list specific construction materials. Structurally, GeneRotex 24 uses a rotary mixing mechanism, a 7-inch color LCD touchscreen, and specialized 15 mL single reaction tubes with stirring sleeves. The system includes negative pressure, HEPA filtration, and UV disinfection. Its published dimensions are 490×540×480 mm, with a net weight of 45 kg.
GeneRotex 24 is applicable to molecular diagnostics, public health laboratories, and biomedical research. These segments can use the system for automated nucleic acid extraction workflows that require 1-24 sample throughput and processing volumes from 50 to 15000 µL.
For application-specific requirements, share your sample type, sample volume, and throughput needs with Tianlong’s technical team so compatibility with the GeneRotex 24 can be reviewed. The published specification covers the GeneRotex 24 model and its specialized 15 mL single reaction tubes and stirring sleeves.
GeneRotex 24 processes 1-24 samples per run.
The processing volume range is 50-15000 µL, and the sample volume is 5000 µL.
The mixing method is rotary mixing, which helps reduce aerosol generation.
The system is equipped with negative pressure, HEPA filtration, and UV disinfection.
It uses specialized 15 mL single reaction tubes and stirring sleeves. Single reaction tubes support independent sample extraction.
Lysis and elution heating operate from ambient to 120°C.
The instrument has a 7-inch color LCD touchscreen, measures 490×540×480 mm (L×W×H), and has a net weight of 45 kg.
Applicable industries include molecular diagnostics, public health laboratories, and biomedical research.