{{ variable.name }}
Four fluorescence channels, Peltier thermal cycling and a 7-inch touchscreen in an 11 kg benchtop instrument.
The Gentier 48E is a 48-well real-time PCR system from Tianlong's Gentier 48 Series, designed for laboratories running small to mid-sized qPCR batches. It processes 1 to 48 samples per run across four fluorescence channels, with a fluorescence scanning time of 2 seconds and Peltier-based thermal cycling at maximum heating and cooling rates of at least 8.0°C/s and 6.2°C/s. Temperature control accuracy is ≤0.1°C, and a 1–40°C gradient interval supports annealing optimisation. Operators can run the instrument from the onboard 7-inch touchscreen or from a connected PC, which allows quantitative analysis, melting curve analysis and SNP analysis in molecular diagnostics, public health and biomedical research settings.

Gentier 48 Series real-time PCR instrument — brochure reference image.
| Parameter | Specification |
|---|---|
| Throughput | 1–48 samples |
| Fluorescence channels | 4 |
| Fluorescence scanning time | 2 s |
| Heating method | Peltier |
| Maximum heating rate | ≥8.0°C/s |
| Maximum cooling rate | ≥6.2°C/s |
| Temperature control accuracy | ≤0.1°C |
| Gradient interval | 1–40°C |
| Display | 7-inch touchscreen |
| Dimensions (W×L×H) | 260×400×260 mm |
| Net weight | 11 kg |
| Operation modes | Standalone (touchscreen) or PC operation |
| Analysis types | Quantitative analysis, melting curve analysis, SNP analysis |
The Gentier 48E is the 48-well, four-channel model in the Gentier 48 Series. Tianlong's real-time PCR portfolio also covers the Gentier X3, Gentier Sp96, Gentier Mini and Gentier 96 series, which lets a laboratory standardise instrument families across different throughput classes. Two documented operating configurations apply to the 48E: standalone control through the integrated 7-inch touchscreen, or control from a connected PC. The published datasheet does not list optional accessories, so any additional items should be confirmed with the sales team before ordering.
The instrument is built around a Peltier thermal module with four optical fluorescence channels, an integrated 7-inch touchscreen and a chassis measuring 260×400×260 mm at a net weight of 11 kg. Housing and block material specifications are not stated in the published datasheet; request the current material documentation from Tianlong if your procurement or validation process requires it.
The Gentier 48E is specified for molecular diagnostics, public health laboratories and biomedical research. In Tianlong deployments, comparable real-time PCR workflows are used for disease diagnosis, clinical auxiliary diagnosis, companion diagnostics, health check-ups, screening for blood-borne infectious diseases, customs inspection and quarantine, and epidemiological analysis. Typical buying organisations include centres for disease control and prevention, clinical hospitals, inspection and quarantine stations, customs laboratories, research institutes, the livestock farming sector and blood banks.
Workflow adaptation is handled through documented instrument capabilities rather than speculative options. The 1–40°C gradient lets a laboratory optimise annealing conditions for its own primers and probes; the four fluorescence channels define how many targets can be multiplexed per run; and the choice between standalone and PC operation is set at installation. Because Tianlong manufactures both instruments and reagents — including PCR reagent kits at a stated capacity of 250,000+ kits per year — assay and instrument sourcing can be coordinated with one supplier. Private-label or OEM terms are not published and must be discussed directly with the sales team.
Customer profile: centres for disease control and prevention, clinical hospitals, inspection and quarantine stations, customs, research institutes, the livestock farming sector and blood banks.
Project scale: US$50,000–200,000 per engagement.
Relationship duration: 3–5 years.
Reported outcome: customer satisfaction scores and a zero accident rate for projects.
Highlighted by the supplier: detection accuracy, stable performance, and compliance with international medical testing standards.
How many samples can one run hold?
The Gentier 48E handles 1–48 samples per run, with four fluorescence channels available for multiplex detection.
Can the instrument run without a computer?
Yes. The system supports standalone operation through its 7-inch touchscreen, and it can also be controlled from a connected PC.
Which analysis types are supported?
Quantitative analysis, melting curve analysis and SNP analysis, as listed in the product specification.
What temperature performance should we plan for?
Peltier heating with a maximum heating rate of ≥8.0°C/s, a maximum cooling rate of ≥6.2°C/s, and temperature control accuracy of ≤0.1°C.
What gradient range is available for assay optimisation?
The gradient interval is 1–40°C, allowing several annealing temperatures to be tested in a single experiment.
What bench space and weight do we need?
Dimensions are 260×400×260 mm (W×L×H) and net weight is 11 kg.
What regulatory background does the manufacturer hold?
Tianlong states more than 90 medical device registrations in China and 300+ international certifications and regulatory approvals, including CE, FDA-related and KFDA-related credentials.
How are price, MOQ and lead time handled?
Commercial terms are quoted per project and are not published on the product page. Send your throughput requirement and application details to the sales team for a quotation.
Xi'an Tianlong Science and Technology Co., Ltd.
Email: inquiry@medtl.com | Telephone: +86-29-82682132 | WhatsApp: +86 18182667606
Address: 4266 Shanglin Road, Xi'an 710021, China | Website: www.medtl.net