{{ variable.name }}
SEO Title: 450nm Blue 10W Portable ENT Diode Laser with 7-Inch Touchscreen
Meta Description: PIOON S1-C10 ENT laser system delivers 450nm blue light up to 10W for soft tissue cutting and coagulation, with a 7-inch touchscreen and a 2kg alloy body.
URL Slug: /pioon-s1-c10-450nm-ent-diode-laser
The PIOON S1-C10 ENT is a medical diode laser built for minimally invasive ear, nose and throat procedures. Its 450nm wavelength is strongly absorbed by hemoglobin, supporting precise soft tissue cutting, coagulation and vaporization in narrow anatomical spaces.
PIOON S1-C10 450nm blue diode laser, 10W, ABS+PC housing with metal components
S1-C10 combines a 450nm blue laser source, up to 10W output and a 7-inch RETINA touchscreen in a housing measuring 260 × 125 × 200mm with a net weight of no more than 2kg. Continuous Wave and Pulsed modes let clinicians match energy delivery to the tissue interaction required by the procedure.
The system runs on a standard SMA905 connector and accepts medical optical fibers of 200μm and above, including bare and polyimide-coated fibers, plus ENT surgical handpieces with interchangeable cannulas for ear, nasal cavity, pharynx and larynx access. A 2850mAh battery and an aluminum-magnesium alloy case make the unit practical to move between consulting rooms, clinics and hospital ENT departments.
S1-C10 ENT with 7-inch Retina touchscreen (PPI > 340) for presets and power adjustment
450nm Blue Wavelength
Strong hemoglobin absorption supports cutting, coagulation and vaporization, helping clinicians manage bleeding and keep the surgical field clear.
Up to 10W in CW or Pulsed Mode
Choose continuous or pulsed delivery to match the tissue response required by different ENT procedures.
Contact and Non-Contact Technique
Compatible optical fibers allow both contact cutting and non-contact vaporization and coagulation within one system.
7-Inch Retina Touchscreen
PPI > 340 interface gives direct access to treatment presets, power adjustments and operating settings.
Dual Fan and Electronic Cooling
Multi-channel copper tube heat dissipation supports stable laser operation during clinical procedures.
≤2kg Transport Weight
Aluminum-magnesium alloy case and compact 260 × 125 × 200mm footprint simplify transport and positioning in ENT clinics and outpatient facilities.
| Laser Type | Medical diode laser (ENT) |
|---|---|
| Wavelength | 450 nm (±20 nm) |
| Maximum Output Power | 10 W (best balanced configuration) |
| Operating Modes | Continuous Wave (CW) / Pulsed |
| Display / Connection | 7-inch RETINA touchscreen, HDR, PPI > 340 |
| Aiming Beam | 650 nm, < 5 mW, adjustable density |
| Fiber Connection | SMA905 direct connect, medical fiber ≥200 μm |
| Cooling | Dual fan + electronic cooling, multi-channel copper tube |
| Battery Capacity | 2850 mAh |
| Net Weight | ≤ 2 kg (without case) |
| Dimensions (L×W×H) | 260 × 125 × 200 mm |
| Housing | ABS+PC housing with metal components |
| Case | Aluminum-magnesium alloy case |
| Power Supply | 100–240 V AC, 50/60 Hz |
The S1-C10 described here is the 450nm blue configuration. PIOON's ENT education and distributor programs also cover 980nm diode laser technology as a separate wavelength option, so buyers should confirm the wavelength that matches their approved indications before ordering.
The unit uses an ABS+PC housing with metal components and is supplied in an aluminum-magnesium alloy case, keeping net weight at or below 2kg. Inside, a dual fan plus electronic cooling system with multi-channel copper tubes manages heat during operation. The front panel uses a standard SMA905 fiber port for direct connection of medical fibers of 200μm and above, so no additional adapter is required. A 650nm aiming beam with adjustable density marks the target area before firing.
Fiber-delivered S1-C10 ENT laser for minimally invasive ear, nose, throat and pharynx procedures
Otology
Selected procedures involving delicate ear structures, including stapedotomy and cholesteatoma management.
Rhinology
Turbinate reduction, nasal scar tissue treatment and selected nasal soft tissue procedures.
Laryngology
Laser-assisted management of vocal cord polyps, papillomas, cysts, capillary ectasia and other selected laryngeal lesions.
Pharyngology
Tonsillar procedures and selected pharyngeal soft tissue surgery.
PIOON offers OEM/ODM services backed by in-house laser module, PCB, precision machining and medical optical fiber production. Distributor support includes product training, technical assistance, clinical education resources, regulatory documentation and after-sales service. Accessory configuration, including fiber type, ENT handpiece cannula lengths, foot pedal and safety eyewear, can be agreed with the supplier before order placement.
For at least two years, PIOON has run product demonstration, professional education and technical exchange activities for ENT clinics, hospital ENT departments, otolaryngologists, medical equipment distributors and surgical laser distribution partners. The sessions cover 450nm and 980nm diode laser technologies together with compatible optical fibers and potential clinical workflows.
These activities introduced laser system features, wavelength options and compatible accessories, and supported technical knowledge sharing between medical professionals and distributors. No clinical outcome data is claimed.
What wavelength and power does the S1-C10 ENT deliver?
450nm ±20nm with a maximum output of 10W, in Continuous Wave or Pulsed mode.
Which fibers and handpieces are compatible?
Any medical fiber of 200μm or above with a standard SMA905 connector, including bare and polyimide-coated fibers. ENT surgical handpieces with interchangeable cannulas are available.
Does the system support non-contact treatment?
Yes. S1-C10 supports both contact and non-contact techniques through compatible optical fibers.
How is the device powered and cooled?
100–240 V AC, 50/60 Hz input, a 2850mAh battery, and dual fan plus electronic cooling with multi-channel copper tubes.
How portable is the unit?
Net weight is no more than 2kg and dimensions are 260 × 125 × 200mm, supplied in an aluminum-magnesium alloy case.
What quality and regulatory evidence is available?
PIOON operates an ISO 13485:2016 quality management system certified by TÜV SÜD Product Service GmbH, holds an EC Certificate under MDD 93/42/EEC Annex II excluding (4) for therapy laser and medical diode laser scope, and an EMC certificate of conformity for the EU/EEA market.
What support do distributors receive?
Product training, technical assistance, clinical education resources, regulatory documentation, after-sales service and OEM/ODM cooperation.
Email: sales@pioon.com | WhatsApp: +86 18971249550
Tel: +86 27 87001110 | Web: www.pioon.com
Wuhan Pioon Technology Co., Ltd, 12th Floor, Building 1, Innovative Unit, R&D Center Project, Marine World Shipbuilding Park, No. 16, Fozuling 3rd Road, East Lake High-tech Development Zone, 430205, Wuhan, Hubei, China