القائمة

8 MVA Dual-Split Winding Substation Power Transformer for Solar Storage

جرد:
SKU: 3235642064
الطراز: Substation & Power Transformers

{{ variable.name }}

{{ value.name }}

8 MVA Dual-Split Winding Substation Power Transformer for Solar Storage

Collector-side oil-immersed transformer with two low-voltage split windings and a 34.5 kV output, built for co-located solar farms and battery energy storage plants.

8 MVA dual-split winding substation power transformer for solar and storage plants

8 MVADual LV split winding34.5 kV outputHarmonic load toleranceIEEE C57

Product Summary

This 8 MVA oil-immersed substation transformer is designed for hybrid renewable plants where PV inverters and battery power conversion systems share one grid connection point. Two low-voltage split windings allow a single unit to serve multiple converter groups, while the 34.5 kV output feeds the plant collector system for a stable grid interconnection. High thermal margin insulation and harmonic-tolerant design address the fluctuating, converter-driven load profile of solar and storage duty. The unit is part of a substation and power transformer line spanning 150 kVA to 1000 MVA and 2.4 kV to 1000 kV, all built to project specification.

Key Features

Dual LV split winding architecture

Two low-voltage split windings let one transformer serve separate converter groups, simplifying collector design for co-located PV and storage blocks.

8 MVA at 34.5 kV output

A single 8 MVA unit delivers a stable 34.5 kV collector voltage for renewable energy grid interconnection and dispatch.

High thermal margin insulation

The insulation system is sized with thermal margin so daily load cycling from solar output and storage dispatch does not erode service life.

Harmonic load resistance

Designed to tolerate inverter and PCS harmonics typical of hybrid renewable plants, supporting power quality at the point of interconnection.

IEEE C57 compliant build

Project build follows IEEE C57 requirements, with ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076 and DOE efficiency als

Technical Specifications

Rated capacity8 MVA
Output voltage34.5 kV collector level
Low-voltage windingsDual split winding architecture
Insulation systemHigh thermal margin insulation
Harmonic performanceSpecified for harmonic load resistance from inverters and PCS
CoolingONAN / ONAF / OFAF / ODAF, project-specified
Tap changerOLTC or DETC
Core and conductorsGrain-oriented silicon steel core, copper or aluminum windings
StandardsIEEE C57 project build; line also offered to ANSI/IEEE C57, CSA C88, AS 60076, IEC 60076, DOE efficiency
TestingRoutine and project-specified FAT with serialized reports
Lead time10 to 20 weeks typical; 13-week delivery achieved on the referenced solar storage project
Warranty24 months from B/L date, extendable to 5 years

Models and Options

Capacity, winding split, impedance and cooling are configurable around the 8 MVA reference point. Ancillary options include conservator or sealed-tank construction, porcelain or polymer bushings, air terminal chambers, and integrated Buchholz relay, pressure relief device and temperature indicators.

  • Two-winding or split-winding low-voltage configurations
  • OLTC for voltage regulation under variable renewable output
  • Custom tank footprint and transport bracing for remote plant sites

Materials and Structure

Low-loss grain-oriented silicon steel cores and precision-wound copper or aluminum conductors are combined with oil-immersed cooling to keep losses and temperature rise controlled under cyclic loading. Manufacturing takes place in 45,000 m2 facilities under ISO 9001, ISO 14001 and ISO 45001 certified systems.

Applications

  • Utility-scale solar farms and co-located PV plus storage plants
  • Battery energy storage system collector substations
  • Hybrid renewable energy plants and grid-scale solar storage projects
  • Plant auxiliary power distribution at renewable generation sites

Customization

Winding split ratio, impedance, tapping range, cooling class and protection scope are engineered per project. Drawings and factory test plans are approved before production begins.

Case Study: 8 MVA Unit for a U.S. Solar-Plus-Storage Plant

A U.S. renewable energy developer ordered one 8 MVA transformer for a utility-scale solar farm combined with a battery energy storage system. The unit was delivered with a dual low-voltage split winding architecture, high thermal margin insulation and harmonic load resistance, built to IEEE C57 requirements.

  • 90-day fast lead time delivery
  • Smooth PV storage grid connection with stable 34.5 kV voltage output
  • Reliable renewable energy grid interconnection and seamless solar storage power dispatch
  • Design life of 30 years

FAQ

Why use a dual split winding instead of a standard two-winding unit?
Two low-voltage split windings allow one transformer to serve separate inverter or PCS groups, which reduces the number of transformers and interconnecting cables on the collector system.

Is this transformer suitable for storage-only projects?
Yes. It is applied to solar-plus-storage and hybrid renewable plants, where charge and discharge cycles plus PV output create the fluctuating load profile the design is specified for.

How do you handle inverter harmonics?
The transformer is specified for harmonic load resistance, and impedance and thermal design are set against the converter harmonic spectrum supplied with the project data.

What is the typical lead time?
Standard lead time is 10 to 20 weeks depending on capacity and specification; a 90-day delivery was achieved on the referenced solar storage project.

Are factory test reports supplied?
Yes. Routine and project-specified factory acceptance tests are performed and serialized reports are issued before shipment.

Inquiry Information

Share your inverter and PCS output, collector voltage, harmonic data and site ambient conditions for a project-specific design proposal.

Contact: Mr. Steven
Email: steven@winley-electric.com
Tel: 86-18650108051
WhatsApp: +8618650108051
Address: No. 99 Yilan Road, Siming, Xiamen, Fujian, China

Image Filenames and Alt Text Suggestions

  • 8mva-solar-storage-dual-split-transformer.png - 8 MVA dual split winding substation power transformer for solar and storage plants

SEO Title: 8 MVA Dual-Split Winding Transformer for Solar and Storage Plants

Meta Description: 8 MVA dual-split winding substation transformer for co-located solar and battery storage plants. 34.5 kV output, IEEE C57 design, 90-day project delivery.

URL Slug: 8mva-solar-storage-dual-split-transformer