Integrated screw airend with altitude oxygen compensation intake port. Operates up to 5,000 m, -40°C to +50°C, oil carry-over ≤3 ppm. 18-22 kW, 2.5-3.3 m³/min.
gcu30-high-altitude-screw-airend

GCU30 High-Altitude Screw Airend for Plateau Oxygen Supply

GCU30 high-altitude screw airend for plateau oxygen supply with altitude compensation intake port

The GCU30 High-Altitude configuration is specifically adapted for plateau locomotive and coach oxygen supply systems, as well as on-board oxygen and nitrogen generation. It features an altitude oxygen compensation intake port and is designed for operation at altitudes up to 5,000 m with stable pressure and delivery.

Based on the GCU30 Engineering integrated screw airend, this configuration maintains the 9-in-1 compact design while adding cold-weather capability down to -40°C and high-temperature operation up to +50°C. The low oil carry-over ensures clean, water-free compressed air for sensitive oxygen and nitrogen generators.

Key Features

Altitude Oxygen Compensation
Intake port designed for thin air at altitudes up to 5,000 m.
Wide Temperature Range
Operating range -40°C to +50°C for plateau day/night temperature swings.
Low Oil Carry-Over
<2 ppm (design ≤3 ppm) for clean oxygen/nitrogen generation.
9-in-1 Integration
Screw airend + oil-gas separator + 3 filters + 4 valves in one compact unit.
Reliable at Altitude
Case-proven at 5,000 m with stable pressure and delivery.
Compact and Lightweight
96 kg, 560×490×580 mm, suitable for on-board installation.

Technical Specifications

ParameterValue
ModelGCU30 Engineering (high-altitude configuration)
Power18-22 kW
Speed2900-6000 rpm
FAD @ 7 bar2.5-3.3 m³/min
Max. / Min. Working Pressure12.5 / 5 bar
Max. Discharge Temperature105 °C
Oil Carry-Over<2 ppm (design ≤3 ppm)
Noise≤75 dB(A)
Net Weight96 kg
Dimensions (L×W×H, excl. air filter)560×490×580 mm
Configuration9-in-1: screw airend + oil-gas separator tank + 3 filters + 4 valves
Altitude AdaptationUp to 5,000 m (high-altitude configuration)

Models and Options

Base model: GCU30 Engineering. High-altitude configuration includes:

  • Altitude oxygen compensation intake port
  • -40°C to +50°C operating temperature design
  • Dry and oil-free air with oil carry-over ≤3 ppm (design)
  • Optional air filter assembly for dusty plateau conditions

Materials and Structure

The high-altitude configuration retains the robust construction of the GCU30 Engineering: high-grade cast iron housing, forged alloy steel rotors with German-designed UV patented profile, SKF heavy-duty bearings, and triple-sealing technology. The integrated oil separation system combines a built-in coarse separator with an oversized external fine separator. Additional sealing and intake modifications support low-temperature and low-pressure operation.

Applications

Designed for plateau applications, including:

  • Locomotive and coach oxygen-enrichment systems
  • On-board oxygen and nitrogen generation
  • Plateau rail transit air supply
  • Other high-altitude mobile equipment requiring clean compressed air

Case Study: A plateau locomotive and coach oxygen supply project has used 300 units over 2 years. The GCU30 high-altitude configuration operates normally at altitudes up to 5,000 m with stable pressure and delivery. The altitude oxygen compensation intake port and -40°C to +50°C design ensure reliability in extreme conditions. Another aftermarket project has shipped approximately 300 units cumulatively, with CE-compliant supply, drop-in replacement dimensions, and 25-30% lower purchase cost than comparable European airends.

Customization

We can tailor the high-altitude configuration to your specific altitude, temperature range, and air quality requirements. Please provide your operating conditions for a customized solution.

FAQ

Q: What is the maximum altitude for this configuration?
A: The high-altitude configuration is designed for operation up to 5,000 m, with an altitude oxygen compensation intake port to maintain performance in thin air.
Q: What is the operating temperature range?
A: The high-altitude configuration is designed for -40°C to +50°C, suitable for plateau day/night temperature swings.
Q: Is the air oil-free?
A: Oil carry-over is less than 2 ppm (design ≤3 ppm), providing clean compressed air for oxygen and nitrogen generation.
Q: Can it be used for on-board oxygen generation?
A: Yes, it is specifically used in plateau locomotive and coach oxygen supply projects with on-board oxygen and nitrogen generation systems.
Q: Is CE certification available?
A: Yes, our integrated screw airends are CE certified by TUV Rheinland for the 2.2-45 kW range.
Q: What is the lead time?
A: Lead time varies by configuration and order quantity. Please contact us for current lead times.

Inquiry Information

Email: service@woyo.cn
Tel: +86 510 8599 6655
WhatsApp: +86 189 1237 9878
Address: No.5 Changkang Road, Mashan, Binhu District, Wuxi, Jiangsu, China

Please include your altitude, temperature range, and air demand for a tailored quotation.

Image Filename and Alt Suggestions

Image 1: gcu30-high-altitude-oxygen-supply.png – Alt: 'GCU30 high-altitude screw airend with altitude compensation intake port for plateau oxygen supply'

Image 2: gcu30-high-altitude-temperature-range.png – Alt: 'GCU30 screw airend designed for -40°C to +50°C plateau operation'

Image 3: gcu30-high-altitude-compact-unit.png – Alt: 'Compact GCU30 integrated screw airend for on-board oxygen generation'

Image 4: gcu30-high-altitude-connections.png – Alt: 'Connection ports on GCU30 high-altitude screw airend'