القائمة

OCP UQD Hose Barb Quick Disconnect Socket (Female) for Liquid Cooling

جرد:
SKU: 5546375558
الطراز: 3093312302

{{ variable.name }}

{{ value.name }}

Product Specification

TypeUQD02 Hose Barb Sockets; UQD04 Hose Barb Sockets; UQD06 Hose Barb Sockets; UQD08 Hose Barb Sockets; UQD Female Quick Couplings; EPDM Hose Barb Connectors; Dry-Break UQD Sockets; Liquid Cooling Hose Assembly ConnectorsModelJY-UQD-02B-02R, JY-UQD-02B-02B, JY-UQD-04B-01R, JY-UQD-04B-01B, JY-UQD-06B-01R, JY-UQD-06B-01B, JY-UQD-08B-01R, JY-UQD-08B-01B
ParamsProduct Name: OCP UQD Hose Barb Quick Disconnect Socket (Female) for Liquid Cooling Manufacturer: JINGYE Fittings (Ningbo Jingye Fluid Fittings Co., Ltd.) Sizes: UQD02, UQD04, UQD06, UQD08; eight red/blue socket SKUs. Product Type: Hand-mate flat-face dry-break female coupling with integrated hose barb. 1. Models and Hose Connections UQD02: JY-UQD-02B-02R / JY-UQD-02B-02B; fits 1/4" reinforced EPDM hose. UQD04: JY-UQD-04B-01R / JY-UQD-04B-01B; fits 3/8" reinforced EPDM hose. UQD06: JY-UQD-06B-01R / JY-UQD-06B-01B; fits 1/2" reinforced EPDM hose. UQD08: JY-UQD-08B-01R / JY-UQD-08B-01B; fits 5/8" reinforced EPDM hose. R/B identify red/blue versions. Verify hose inner diameter and retention method for each assembly. 2. Interface and Construction Reference: Open Compute Project Universal Quick Disconnect (OCP UQD) Specification Rev. 1.0. Female socket mates with a corresponding same-size UQD male plug. Hand-mate locking mechanism secures the coupled connection. Flat-face valved design supports low-spill separation and reduced air entry. UQD hand-mate and UQDB blind-mate are distinct interfaces. 3. JINGYE Socket Dimensions UQD02: A/B/C/D = 41.0/20.0/19.0/8.8 mm; 1/4" hose. UQD04: A/B/C/D = 46.4/24.5/25.0/12.0 mm; 3/8" hose. UQD06: A/B/C/D = 52.8/27.0/28.0/15.2 mm; 1/2" hose. UQD08: A/B/C/D = 64.0/25.0/32.0/18.0 mm; 5/8" hose. A/B/C/D follow JINGYE product drawing references. Confirm barb geometry and mating clearances against the selected drawing. 4. Pressure and Temperature JINGYE catalog working pressure: 0 ~ 100 psi (0 ~ 6.9 bar). JINGYE catalog temperature range: -55°C ~ +125°C, subject to selected seal, coolant and assembly configuration. OCP Rev. 1.0 reference: Minimum burst pressure 300 psi (20.7 bar); operating coolant temperature +17°C ~ +65°C; shipping -40°C ~ +75°C. Finished hose assembly pressure is limited by its lowest-rated component. 5. Flow and Pressure Drop OCP Rev. 1.0 reference minimum coupled-pair Cv (water): UQD02 0.25; UQD04 0.80; UQD06 1.60; UQD08 2.50. OCP reference water flow: UQD02 at least 0.55 GPM; UQD04 1.7 GPM; UQD06 3.0 GPM; UQD08 4.7 GPM. Actual Cv and pressure drop depend on the tested socket/plug pair and fluid conditions; verify project-specific flow curves. 6. Fluid Loss and Leakage OCP Rev. 1.0 reference maximum fluid loss per connect/disconnect cycle at 0 psi: UQD02 0.020 mL; UQD04 0.025 mL; UQD06 0.035 mL; UQD08 0.070 mL. The above are OCP qualification limits, not JINGYE measured product results. Project testing may include helium leak checks, coupled/disconnected leakage, air inclusion, fluid loss and pressure testing. 7. Materials, Seals and Coolants Body: SUS304 stainless steel; SUS316L available for selected configurations. Seals: Peroxide-cured EPDM or FKM (Viton), selected by coolant chemistry and temperature. Media: DI water, propylene glycol/water (PGW), ethylene glycol/water (EGW) and compatible single-phase coolant mixtures. Check fluid concentration, wetted-material corrosion, seal swelling and system cleanliness. 8. Hose Assembly and Installation Integrated barb tail connects to a suitably sized reinforced EPDM coolant hose. Hose retention, clamps/crimp sleeves, insertion depth, bend radius, pull-off resistance and leak testing depend on the approved assembly design. Red/blue identification supports supply/return line management. Protect the socket seal and latch from contamination. 9. Quality and Durability Quality management: ISO 9001:2015. Controls: Mating geometry, latch operation, valve movement, barb dimensions, seals, cleanliness, surface finish and visual inspection. Qualification may include coupling force, cycling endurance, thermal cycling, leak tests, fluid loss and cross-mating verification with the intended plug. 10. OEM Applications and Procurement Applications: AI/GPU servers, HPC, direct-to-chip cold plates, CDUs, rack manifolds and serviceable liquid cooling hose assemblies. Supply: Individual sockets, red/blue variants, samples, customized hose tails and complete hose assemblies. For quotation specify UQD size, hose ID/type, hose length, mating plug, coolant, pressure, target flow, seal, quantity and testing requirements.MaterialPrimary Material: Stainless Steel SUS304, suitable for precision-machined OCP UQD hose barb sockets used in data center liquid cooling hose assemblies. Optional Materials: Stainless Steel 316 / 316L for enhanced corrosion resistance and suitable coolant applications. Sealing Materials: Peroxide-cured EPDM or FKM (Viton), selected according to coolant chemistry, operating temperature, and sealing requirements. Coolant Compatibility: Deionized water (DI Water), propylene glycol/water (PGW), ethylene glycol/water (EGW), and compatible single-phase water/glycol cooling fluids. Hose Connection: Precision-machined stainless steel hose barb designed for compatible reinforced EPDM coolant hoses. Wetted Components: Corrosion-resistant stainless steel body, valve components, and sealing surfaces. Material Selection: Based on coolant compatibility, hose material, pressure, temperature, corrosion resistance, and OCP UQD mating requirements.
Applicable IndustryLiquid Cooling Hose Assembly Manufacturing: Reinforced EPDM coolant hose assemblies, hose barb connections, UQD female sockets, and OEM liquid cooling hose production. AI & GPU Server Cooling: AI training servers, GPU clusters, accelerator modules, and high-density liquid-cooled computing systems. Data Center Liquid Cooling: Direct-to-chip (D2C) cooling, server racks, serviceable coolant loops, and OCP-based liquid cooling infrastructure. HPC & Supercomputing: High-performance computing clusters, supercomputers, and liquid-cooled computing equipment. Coolant Distribution Units (CDUs): CDU hose assemblies, coolant supply/return lines, quick disconnect interfaces, and maintenance connections. Rack Manifolds & Cold Plates: Rack-level coolant distribution, cold plate hose connections, and server-side cooling circuits. Liquid Cooling System Integrators & MRO: OEM cooling solutions, hose replacement, UQD socket servicing, and compatible plug connections.

Feature

JINGYE Fittings manufactures OCP UQD hose barb quick disconnect sockets for data center liquid cooling in Ningbo, China. Founded in 2008, we support AI server OEMs, liquid cooling integrators, CDU manufacturers, and hose assembly suppliers. Key Product Advantages: 1. Four UQD Sizes and Eight Socket SKUs UQD02: JY-UQD-02B-02R / JY-UQD-02B-02B, for 1/4" hose. UQD04: JY-UQD-04B-01R / JY-UQD-04B-01B, for 3/8" hose. UQD06: JY-UQD-06B-01R / JY-UQD-06B-01B, for 1/2" hose. UQD08: JY-UQD-08B-01R / JY-UQD-08B-01B, for 5/8" hose. Red/blue variants help identify coolant supply and return lines. 2. OCP UQD Hand-Mate Interface The female socket is designed around the Open Compute Project Universal Quick Disconnect interface and connects with a corresponding same-size UQD male plug. Its hand-mate locking arrangement supports accessible, serviceable coolant circuits. UQD and UQDB are distinct connection families. 3. Flat-Face Dry-Break Design Valved flat-face construction helps limit coolant loss and air inclusion during connection and disconnection. The sealing and shutoff performance depends on the assembled socket/plug pair, coolant, pressure, and operating conditions. 4. Hose Barb Connection for EPDM Assemblies Integrated stainless steel hose barbs support reinforced EPDM cooling hoses in nominal 1/4", 3/8", 1/2", and 5/8" sizes. Hose retention, clamp or crimp sleeve selection, insertion depth, pull-off resistance, and leak testing are specified for each hose assembly design. 5. Flow and Pressure-Drop Engineering OCP UQD Rev. 1.0 reference minimum coupled-pair Cv values: UQD02 0.25; UQD04 0.80; UQD06 1.60; UQD08 2.50. Actual flow and pressure drop depend on the matching plug/socket combination and coolant. Application-specific flow evaluation is supported. 6. Low-Spill Connection Performance OCP Rev. 1.0 reference maximum fluid loss per cycle at 0 psi: UQD02 0.020 mL; UQD04 0.025 mL; UQD06 0.035 mL; UQD08 0.070 mL. These are standard reference limits rather than JINGYE measured results. Leakage and fluid-loss testing can be specified for qualification. 7. Pressure and Temperature Selection JINGYE catalog working pressure: up to 100 psi (6.9 bar). Catalog temperature range: -55°C ~ +125°C, depending on seals, coolant, and configuration. OCP Rev. 1.0 reference coolant operation: +17°C ~ +65°C. Completed hose assemblies are rated by their lowest-rated component. 8. Stainless Steel and Coolant Compatibility Standard socket body: SUS304 stainless steel, with SS316/316L options. EPDM and FKM seal selections can be evaluated for deionized water, propylene glycol/water, ethylene glycol/water, and compatible single-phase coolants. Material approval depends on fluid chemistry, concentration, temperature, and corrosion requirements. 9. CNC Manufacturing and Quality Control JINGYE Fittings uses precision CNC machining and an ISO 9001:2015 quality management system. Inspection focuses on mating geometry, latch operation, valve travel, barb dimensions, sealing faces, cleanliness, and visual quality. Pressure, leakage, and cycle testing can follow agreed project criteria. 10. OEM Hose Assemblies and Second-Source Support OEM options include hose-tail configurations, red/blue identification, selected materials, seals, packaging, and complete cooling hose assemblies. Customers may submit hose drawings and existing UQD plugs for dimensional review, mating trials, and qualification. Cross-brand interchangeability requires physical verification. 11. Data Center Liquid Cooling Applications Designed for AI/GPU servers, HPC, direct-to-chip cold plates, rack manifolds, coolant distribution units (CDUs), and serviceable liquid cooling loops. JINGYE Fittings supports sampling, mixed-SKU orders, OEM development, and repeat production for liquid cooling equipment manufacturers.

OCP UQD Hose Barb Quick Disconnect Socket (Female) for Liquid Cooling

OCP UQD Hose Barb Quick Disconnect Socket (Female) for Liquid Cooling