القائمة

OCP UQD Male Thread Quick Disconnect Socket (Female) for Data Center Liquid Cooling

جرد:
SKU: 1596079460
الطراز: 3778307444

{{ variable.name }}

{{ value.name }}

Product Specification

TypeUQD02 Male Thread Sockets; UQD04 Male Thread Sockets; UQD06 Male Thread Sockets; UQD08 Male Thread Sockets; SAE ORB Thread UQD Sockets; OCP UQD Female Couplings; CDU Liquid Cooling Connectors; Rack Manifold UQD SocketsModelJY-UQD-02B-03R, JY-UQD-02B-03B, JY-UQD-04B-02R, JY-UQD-04B-02B, JY-UQD-06B-02R, JY-UQD-06B-02B, JY-UQD-08B-02R, JY-UQD-08B-02B
ParamsProduct Name: OCP UQD Male Thread Quick Disconnect Socket (Female) for Data Center Liquid Cooling Manufacturer: JINGYE Fittings (Ningbo Jingye Fluid Fittings Co., Ltd.) Sizes: UQD02, UQD04, UQD06, UQD08; 8 red/blue threaded socket SKUs. Configuration: Hand-mate female quick disconnect socket with male SAE ORB threaded end. 1. Models and Part Numbers UQD02: JY-UQD-02B-03R / JY-UQD-02B-03B. UQD04: JY-UQD-04B-02R / JY-UQD-04B-02B. UQD06: JY-UQD-06B-02R / JY-UQD-06B-02B. UQD08: JY-UQD-08B-02R / JY-UQD-08B-02B. R/B: Red/blue identification versions for coolant circuit management. 2. UQD Interface and Design Interface Reference: Open Compute Project (OCP) Universal Quick Disconnect UQD specification Rev. 1.0. Mating End: Female UQD socket for a matching same-size male UQD plug. Equipment End: Male straight-thread termination for compatible CDU or rack-manifold ports. Function: Flat-face, valved, low-spill hand-mate coupling with socket-side locking mechanism. UQD hand-mate and UQDB blind-mate are distinct connection systems. 3. Threads and JINGYE Dimensions UQD02: 7/16-20 UNF-2A; A/B/C/D = 41.0/8.0/19.0/15.0 mm. UQD04: 9/16-18 UNF-2A; A/B/C/D = 46.4/10.0/25.0/21.0 mm. UQD06: 3/4-16 UNF-2A; A/B/C/D = 52.8/12.0/28.0/24.0 mm. UQD08: 7/8-14 UNF-2A; A/B/C/D = 64.0/12.0/32.0/27.0 mm. A/B/C/D are dimensions on JINGYE product drawings. Verify mating-port thread, O-ring seat/groove, port standard and installation envelope before assembly. 4. Working Pressure and Temperature JINGYE Catalog Working Pressure: 0 ~ 100 psi (0 ~ 6.9 bar). JINGYE Catalog Temperature: -55°C ~ +125°C, depending on selected seals and coolant. OCP Rev. 1.0 Requirements: Maximum operating pressure 100 psi; minimum burst pressure 300 psi (20.7 bar); operating coolant temperature +17°C ~ +65°C; shipping -40°C ~ +75°C. System ratings depend on the complete mating pair and connected hardware. 5. Flow and Pressure Drop OCP Rev. 1.0 Minimum Cv for coupled pair (water): UQD02 ≥0.25; UQD04 ≥0.80; UQD06 ≥1.60; UQD08 ≥2.50. OCP Reference Water Flow: UQD02 ≥0.55 GPM; UQD04 ≥1.7 GPM; UQD06 ≥3.0 GPM; UQD08 ≥4.7 GPM. Actual Cv, flow and differential pressure depend on plug/socket combination, coolant viscosity and test conditions. Obtain configuration-specific test results for system qualification. 6. Coolant Loss and Leakage OCP Rev. 1.0 Maximum Fluid Loss per connect/disconnect cycle at 0 psi: UQD02 0.020 mL; UQD04 0.025 mL; UQD06 0.035 mL; UQD08 0.070 mL. These are OCP performance requirements, not JINGYE measured results. Testing Options: Connected/disconnected leakage, helium leakage, pressure integrity, fluid loss, and air inclusion according to project criteria. 7. Materials, Seals and Coolants Standard Body: SUS304 stainless steel; SUS316L optional. Seals: Peroxide-cured EPDM or FKM (Viton) selected for operating conditions. Typical Coolants: Deionized water, propylene glycol/water (PGW), ethylene glycol/water (EGW), and qualified single-phase water/glycol mixtures. Review coolant additives, corrosion compatibility, seal swelling and wetted-component cleanliness. 8. Installation and Reliability Install the male threaded end into a compatible port using the specified sealing arrangement and tightening procedure. Confirm socket-to-plug size matching, full latch engagement, port sealing, clearance, and supply/return identification. Qualification can include insertion/removal force, life-cycle endurance, thermal cycling, pressure-drop testing, leakage and cross-mating evaluation. 9. Manufacturing and Inspection Quality Management: ISO 9001:2015. Manufacturing: Precision CNC production and OEM support for threaded UQD sockets. Checks: Thread dimensions, mating interface, sealing faces, valve travel, latch engagement, cleanliness, visual condition and traceability as required. Optional documentation: Drawings, material records, inspection data and project-specific test reports. 10. Applications and Procurement Applications: Coolant Distribution Units (CDUs), rack manifolds, distribution blocks, AI/GPU server cooling, HPC, direct-to-chip cold plates and serviceable coolant loops. Customization: Threaded ends, material and seal options, red/blue identification and packaging. RFQ Details: UQD size, SKU, mating plug, thread/port drawing, coolant, temperature, pressure, target flow, quantity and qualification requirements. Second-source review can include dimensional comparison and physical mating tests with customer-supplied plugs.MaterialPrimary Material: Stainless Steel SUS304, suitable for precision-machined OCP UQD male-thread sockets used in CDU and rack manifold liquid cooling systems. Optional Materials: Stainless Steel 316 / 316L for enhanced corrosion resistance and selected coolant applications. Sealing Materials: Peroxide-cured EPDM or FKM (Viton), selected according to coolant chemistry, operating temperature, and sealing requirements. Coolant Compatibility: Deionized water (DI Water), propylene glycol/water (PGW), ethylene glycol/water (EGW), and compatible single-phase water/glycol cooling fluids. Threaded Connection: Precision-machined SAE ORB male straight threads with compatible port sealing arrangements. Wetted Components: Corrosion-resistant stainless steel body, valve components, and sealing surfaces. Material Selection: Based on coolant compatibility, pressure, temperature, port sealing, corrosion resistance, and OCP UQD mating requirements.
Applicable IndustryCoolant Distribution Unit (CDU) Manufacturing: CDU supply/return ports, coolant distribution modules, serviceable fluid connections, and liquid cooling equipment OEMs. Rack Manifold & Distribution Systems: Rack-level coolant manifolds, distribution blocks, SAE ORB threaded ports, and UQD female socket connections. AI & GPU Server Cooling: AI training servers, GPU clusters, accelerator systems, and high-density liquid-cooled computing infrastructure. Data Center Liquid Cooling: Direct-to-chip (D2C) cooling systems, server rack cooling loops, and OCP-based liquid cooling infrastructure. HPC & Supercomputing: High-performance computing clusters, supercomputers, and liquid-cooled computing equipment. Liquid Cooling System Integrators: CDU manufacturers, rack cooling solution providers, fluid distribution equipment suppliers, and OEM system integrators. Data Center Maintenance & MRO: UQD threaded socket replacement, CDU port servicing, rack manifold maintenance, and coolant circuit up

Feature

JINGYE Fittings manufactures OCP UQD male-thread quick disconnect sockets for data center liquid cooling in Ningbo, China. Founded in 2008, we supply CDU manufacturers, rack manifold OEMs, AI server cooling integrators, and component distributors. Key Product Advantages: 1. Four UQD Sizes and Eight Actual SKUs UQD02: JY-UQD-02B-03R / JY-UQD-02B-03B. UQD04: JY-UQD-04B-02R / JY-UQD-04B-02B. UQD06: JY-UQD-06B-02R / JY-UQD-06B-02B. UQD08: JY-UQD-08B-02R / JY-UQD-08B-02B. Red and blue identification options support coolant supply and return line management. 2. OCP UQD Hand-Mate Female Interface The UQD socket is the female quick disconnect half, designed to mate with a corresponding same-size UQD plug. Its locking mechanism supports accessible, serviceable coolant circuits. UQD hand-mate and UQDB blind-mate interfaces are different systems. 3. SAE ORB Male Thread for Fixed Equipment Ports The equipment end has a male straight-thread connection: UQD02 7/16-20 UNF-2A; UQD04 9/16-18 UNF-2A; UQD06 3/4-16 UNF-2A; UQD08 7/8-14 UNF-2A. SAE ORB port sealing is separate from the UQD mating-face seal. Match thread, O-ring, port design, and assembly procedure to the CDU or manifold. 4. Low-Spill Flat-Face Dry-Break Design Valved flat-face construction helps reduce coolant leakage and air entry during servicing. Socket latching and valve operation are designed for repeated manual connection and disconnection. Actual shutoff performance depends on the matched plug/socket pair. 5. Flow and Pressure-Drop Considerations OCP UQD Rev. 1.0 reference minimum Cv values for coupled pairs are UQD02 0.25, UQD04 0.80, UQD06 1.60, and UQD08 2.50. Actual pressure drop depends on the mating plug, coolant viscosity, flow rate, and test conditions. Model-specific qualification supports CDU and manifold sizing. 6. Fluid Loss and Leakage Requirements OCP Rev. 1.0 reference maximum fluid loss per cycle at 0 psi: UQD02 0.020 mL; UQD04 0.025 mL; UQD06 0.035 mL; UQD08 0.070 mL. These are standard reference limits, not JINGYE measured test results. Leakage, fluid-loss, and pressure tests can be specified for OEM projects. 7. Pressure and Temperature Selection JINGYE catalog working pressure is up to 100 psi (6.9 bar); catalog temperature range is -55°C ~ +125°C, depending on seals, coolant, and configuration. The OCP Rev. 1.0 reference coolant operating range is +17°C ~ +65°C. The complete liquid cooling system is limited by its lowest-rated component. 8. Stainless Steel and Coolant Compatibility Standard body material is SUS304 stainless steel, with SS316/316L options. EPDM and FKM seals can be selected for compatible deionized water, propylene glycol/water (PGW), ethylene glycol/water (EGW), and single-phase water/glycol coolants. Verify additives, concentration, corrosion, and seal compatibility. 9. Precision Manufacturing and Inspection JINGYE Fittings applies precision CNC machining and an ISO 9001:2015 quality management system. Inspection covers SAE ORB threads, port sealing surfaces, UQD mating geometry, socket latch, valve travel, cleanliness, and visual condition. Cycling, leak, pressure, and cross-mating tests may be arranged to agreed criteria. 10. OEM and Alternative-Source Support Options include red/blue identification, selected seals, stainless grades, threaded-end customization, packaging, and project documentation. Customers can provide a mating plug, port drawing, or existing coupling reference for dimensional comparison and physical qualification. Interface similarity alone does not establish cross-brand interchangeability. 11. CDU, Rack Manifold, and AI Cooling Applications The threaded female socket is suited to CDU supply/return ports, rack manifolds, coolant distribution blocks, AI/GPU server cooling, HPC, and direct-to-chip liquid cooling loops. JINGYE Fittings supports sample evaluation, mixed-SKU orders, OEM development, and repeat supply.

OCP UQD Male Thread Quick Disconnect Socket (Female) for Data Center Liquid Cooling

OCP UQD Male Thread Quick Disconnect Socket (Female) for Data Center Liquid Cooling