{{ variable.name }}

PIOON M3 podiatry diode laser with 7-inch HD touchscreen and 15W 980nm output.
The PIOON M3 is a 980nm medical diode laser built for podiatry, dermatology and professional foot care. It delivers up to 15W of laser energy and is controlled through PIOON Smart OS on a 7-inch HD vivid touchscreen, while a proprietary laser stabilization system manages heat inside the laser module. The SMA905 port accepts 400µm and 600µm medical fibers, and continuous wave, pulsed and single pulse modes let clinicians match energy delivery to each procedure. The polymer-composite housing measures 210 x 165 x 160 mm.
Up to 15W at 980nm with adjustable output; 980nm interaction with hemoglobin and water supports localized thermal treatment and soft tissue coagulation.
Clinical treatment presets and direct parameter adjustment make the interface usable for experienced clinicians and new team members.
Continuous wave, pulsed and single pulse delivery allow procedure-specific energy control from one platform.
Manages heat generation in the laser module for stable extended use, efficient thermal management and reduced operating noise.
Compatible with 400µm and 600µm medical optical fibers, supporting contact and non-contact treatment delivery.
Fixed focus, surgical zoom and focusing handpieces extend clinical flexibility without adding a second laser platform.
| Laser type | Medical diode laser |
| Wavelength | 980 nm |
| Maximum output power | 15 W |
| Operating modes | Continuous (CW) / Pulse / Single pulse |
| Aiming beam | 650 nm, below 5 mW, adjustable intensity |
| Display | 7-inch HD vivid touchscreen |
| Operating system | PIOON Smart OS |
| Fiber connection | SMA905 |
| Fiber compatibility | 400 µm / 600 µm |
| Handpieces | Fixed focus, surgical zoom, focusing |
| Housing | ABS + PC polymer composite |
| Dimensions (L x W x H) | 210 x 165 x 160 mm |
| Power supply | 18 V DC, 5 A |
| Foot control | Optional wired or Bluetooth foot pedal |
The M3 uses an ABS + PC polymer-composite housing that keeps the unit compact at 210 x 165 x 160 mm for outpatient rooms and foot care benches. Inside, the PIOON laser stabilization control system manages heat generation within the laser module to support stable operation during extended use. The SMA905 fiber port accepts standard medical fibers, and the front panel carries the 7-inch HD touchscreen used to set all parameters.
Laser energy delivered through the nail plate for selected adjunctive onychomycosis protocols.
Supports laser-assisted matricectomy and targeted nail matrix procedures.
Localized laser treatment options for selected plantar wart lesions.
Controlled laser-assisted management of thickened skin.
Treatment options for selected spider veins and telangiectasia.
Supportive laser therapy options for selected conditions involving pain and inflammation.
PIOON provides OEM services, product training, technical assistance and after-sales support for international distributors. Handpiece mix, fiber size and pedal type can be specified when ordering so the delivered configuration matches the procedures a clinic or distributor focuses on.
Clinical applications and treatment outcomes depend on professional assessment, device configuration and locally approved indications.
Podiatry laser demonstration and professional education, global, at least 2 years. PIOON supported product demonstrations, professional education and technical exchanges on diode laser applications in podiatry and foot care with podiatry clinics, foot and ankle specialists, hospital podiatry departments, foot care centers and medical equipment distributors. The activities introduced device functions, compatible treatment accessories and application considerations within the approved intended use, and focused on product education and technical discussion rather than clinical outcome claims.
Which foot care procedures can the M3 980nm laser support?
The system is used for selected adjunctive nail fungus protocols, ingrown toenail and nail matrix procedures, plantar warts, corns and calluses, superficial vascular lesions, and supportive therapy for selected inflammatory foot conditions, subject to locally approved indications.
Which fibers fit the SMA905 port?
The standard SMA905 connector accepts 400µm and 600µm medical optical fibers, giving clinics a choice of fiber size per procedure.
Are continuous and pulsed delivery both available?
Yes. The unit offers continuous wave (CW), pulsed and single pulse modes, selectable from the touchscreen before and during treatment.
How do the three handpieces differ?
The fixed focus handpiece delivers precise energy for selected soft tissue and superficial vascular procedures, the surgical zoom handpiece provides an adjustable spot for non-contact nail and vascular work, and the focusing handpiece provides defined spot sizes for targeted non-contact procedures.
Is the aiming beam adjustable?
The aiming beam operates at 650nm with output below 5mW and adjustable intensity, so the target area can be marked clearly at different working distances.
What documentation supports EU distribution?
PIOON holds an ISO 13485:2016 certificate, a CE certificate under MDD 93/42/EEC Annex II excluding (4), and an EMC certificate of conformity. Confirm the registration status of the exact configuration for your market before import.
Do you provide OEM services and distributor training?
PIOON provides OEM services, product training, technical assistance and after-sales support for international distributors and clinics.
What are the MOQ, price and delivery terms?
MOQ, pricing and delivery schedule depend on the selected configuration and destination market, and are confirmed in the written quotation after your requirements are reviewed.
Wuhan Pioon Technology Co., Ltd. - 12th Floor, Building 1, Innovative Unit, R and D Center Project, Marine World Shipbuilding Park, No. 16, Fozuling 3rd Road, East Lake High-tech Development Zone, 430205, Wuhan, Hubei, China.
Email: sales@pioon.com | Tel: +86 27 87001110 | WhatsApp: +86 18971249550
Share your target procedures, preferred handpieces and fiber size so the quotation matches your clinic or distribution requirements.