Pharmaceutical Reefer Truck +2 to +8°C with Data Logger

Pharmaceutical reefer truck with insulated body for +2 to +8C vaccine transport Temperature-controlled reefer body prepared for pharmaceutical loading Refrigerated truck rear doors on a pharma cold chain vehicle

Product Summary

Pharmaceutical cargo is ordered from the record backwards. This reefer truck is quoted at +2 to +8°C, or -20°C where frozen product is carried, with a temperature recorder and a continuous record supplied as part of the specification. The body is pre-cooled before loading, the unit holds within plus or minus 1°C, and a data logger with one to four sensors produces a USB or printed temperature history for the receiving pharmacy, hospital or distributor. Working conditions are the narrow band, strict traceability, short door-opening tolerance and urban multi-drop delivery that pharmaceutical routes demand.

Key Features

+2 to +8°C documented bandQuoted with a temperature recorder and a continuous record, so the receiver gets the temperature history and the operator has evidence if a claim is raised.
Data logger with 1-4 sensorsUSB or printed record output, with high and low temperature alarms on the controller and a digital set point shown in the cab.
Door-open counterA door switch counts door-open time per trip, which supports the controlled unloading pattern that pharmaceutical work requires.
Hold within plus or minus 1°CPre-cooled body, qualified loading pattern and continuous logging keep the band stable from loading to discharge.
Backup and monitoring optionsDual unit or backup power option, temperature mapping and alarm thresholds, and optional GPS tracking with remote monitoring and alerts.
Hygienic interiorFood-grade FRP or stainless steel 304 lining with coved corners and stainless drain plugs, cleaned between product batches.

Technical Specifications

ItemSpecification
Pharmaceutical set point+2 to +8°C, or -20°C for frozen product
Temperature recordData logger with one to four sensors; USB or printed record
Control and alarmsDigital set point with cab display, high and low temperature alarms, door-open counter
Temperature holdWithin plus or minus 1°C
Pull-downEmpty body from 30°C ambient to 0°C in 30-60 minutes
Working ambient-20 to 45°C
Wall panelFRP 1.5-2.0 mm skins over polyurethane 80-120 mm, 100 mm standard
Interior liningFood-grade FRP or stainless steel 304 with coved corners
DoorsRear double doors standard; strip curtain or side door for multi-drop work
Refrigeration unitNon-independent, self-powered, electric standby or eutectic plates; sized for the coldest set point
RefrigerantR404A standard, low-GWP option on request
Body sizeVolume 10-45 m3; internal length 3,800-9,600 mm
Optional monitoringGPS tracking with remote monitoring and alerts
Warranty12 months major components; unit under unit supplier terms

Models and Options

  • Recorder levels: controller alarms only, or a data logger with one to four sensors and a retrievable record.
  • Power security: dual unit or backup power option, plus electric standby for overnight pre-cooling at the depot.
  • Loading and discharge: rear double doors standard; a loading dock with dock shelter, cold room and backup refrigeration unit are matched equipment on the pharma route.
  • Traceability: door-open counter, GPS tracking with remote monitoring and alerts.

Materials and Structure

FRP 1.5-2.0 mm skins with a food-grade gel coat inside over polyurethane foam of 38-45 kg/m3 foamed under about 120 kPa, a 100-150 mm insulated floor with aluminium T-section rails for return air, stainless rear door frame, hinges, locks and handles, and a multi-lip EPDM gasket. Interior lining is food-grade FRP or stainless steel 304 with coved corners, and drain plugs are stainless or PVC for wash-down between batches.

Applications

  • Pharmaceutical plant and vaccine or biologics distributor transport.
  • Medical device, hospital and laboratory supply runs.
  • Clinical trial logistics and clinical supply distribution.
  • Sample, reagent and temperature-sensitive reagent transport.
  • Hospital and pharmacy delivery on urban multi-drop routes.

Customization

Where a buyer works to a national or international temperature class, the class is turned into a set point and a hold time before body and unit are sized. Temperature mapping and alarm thresholds, dual unit or backup power, retrievable records and GPS monitoring are quoted per project. Any statutory certificate is confirmed project by project with the destination requirement.

FAQ

What set points are available for pharmaceutical cargo?+2 to +8°C as the standard pharmaceutical band, or -20°C where frozen product is carried, both quoted with a temperature recorder and a continuous record.
How many sensors does the data logger take?One to four sensors, with a USB or printed record, and the controller carries high and low temperature alarms with the set point shown in the cab.
Do you supply a cold chain certificate?Any statutory certificate is confirmed project by project. What is supplied as standard with a pharmaceutical build is the temperature record from the logger, plus the body test report among the shipping documents.
Can door-open time be tracked?Yes. A door switch counts door-open time, and GPS tracking with remote monitoring and alerts is available as an option for the operator.
What happens if the unit fails on route?A dual unit or backup power option is quoted for pharmaceutical work, together with a spare-parts kit of filters, belts, gaskets and thermostats and remote help with unit fault codes.
Which documents and terms apply?Invoice, packing list, bill of lading, certificate of origin, insurance, body test report and unit manual, shipped by RoRo or break-bulk under FOB, CIF or DAP, 30-40 working days from down payment.

Inquiry Information

Send the product temperature band, whether frozen product is also carried, the number of drops per day, the receiver requirement for a printed or USB record, and any national requirement the route must meet. Sales engineers then size the body, unit and monitoring package.

Tel: +86-13083602803 · WhatsApp: +86-16638078903 · Email: info@elorry-ind.com · Zhengzhou City, Henan Province, China

Image Filename and Alt Suggestions

reefer-truck-pharma-2-8-body.png — Pharmaceutical reefer truck with insulated body for +2 to +8C vaccine transport.
reefer-truck-pharma-loading-prep.png — Temperature-controlled reefer body prepared for pharmaceutical loading.
reefer-truck-pharma-rear-access.png — Refrigerated truck rear doors on a pharma cold chain vehicle.